← Pump System Design

TDH & NPSHa Calculator

Total dynamic head with Hazen-Williams friction and K-value minor losses, plus NPSH available. For water.

Units & flow

Elevations & pressure

Pump centerline above source water surface. Negative = flooded suction.
Discharge point (or receiving water surface) above pump centerline.
Gauge pressure needed at the outlet. 0 for open discharge.
From the pump curve. Enables margin check.
How it's calculated

All calculations run in US customary units internally and are converted for display. Water properties are taken at the entered temperature.

Warnings flag line velocity outside ~2–10 ft/s (0.6–3 m/s), suction velocity over ~6 ft/s, suction lift over 25 ft, NPSHa at or below zero, and NPSH margin under 10% / 3 ft of NPSHr (or NPSHa under 10 ft if no NPSHr is entered). These are rules of thumb; always confirm against the selected pump's curve.

Results are estimates for planning and training. Verify critical designs against manufacturer data and applicable codes.